3XAM1516MG3-70-250VAC400C2

Circuit Breakers

CIRCUIT BREAKER

3XAM1516MG3-70-250VAC400C2

5925-00-233-5325

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

  • Nominal Thread Size

    0.138 inches

  • Unpackaged Unit Weight

    1.770 pounds

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    6 threaded stud

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Characteristic

    time delay all locations

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    3 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.600 minimum at 200 pct and 3.000 maximum at 200 pct all locations

  • Inclosure Protection Type For Which Designed

    fungus resistant and vibration resistant and shock resistant

  • Frequency In Hertz

    400.0

  • Body Style

    8c multipole-multiple actuator type

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Width

    1.025 inches minimum and 1.035 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.740 inches minimum and 2.760 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.025 inches minimum and 1.035 inches maximum

  • Storage Type

    general purpose warehouse

  • Special Handling Feature

    magnetic

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1500.0 ac all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0

  • Body Length

    3.725 inches minimum and 3.735 inches maximum

  • Body Width

    3.055 inches minimum and 3.065 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    3.040 inches minimum and 3.060 inches maximum

  • Fragility Factor

    moderately rugged

  • Boss Height

    0.155 inches minimum and 0.165 inches maximum

  • Mounting Surface To Terminal End Distance

    3.305 inches minimum and 3.435 inches maximum

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Maximum Continuous Load Current Rating Per Pole

    70.0 amperes ac all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...