0300D0190
Coils and Transformers
TRANSFORMER,POWER
0300D0190
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Frequency Rating
380.0 hertz minimum and 420.0 hertz maximum single component
-
Input-Output Phase Relationship
three phase to three phase single component
-
Transformer Winding Connection Type
wye-delta
-
Winding Tap Location
neutral tap single component single primary
-
~1
ary
-
Thread Series Designator
unc single group
-
Specification/Standard Data
87557-4v15864 manufacturers source control
-
Overall Height
2.500 inches nominal
-
Winding Shielding Method
internally shielded single component
-
Maximum Operating Temp
71.0 deg celsius
-
Inclosure Type
fully inclosed
-
Mounting Facility Quantity
4 single group
-
Mounting Method
threaded hole single group
-
Winding Function And Quantity
1 primary and 2 secondary single component
-
Nominal Thread Size
0.138 inches single group
-
Winding Operating Current
0.2 amperes ac nominal single component all secondary
-
Winding Operating Voltage
180.00 ac volts minimum and 220.00 ac volts maximum single component single prim
-
Winding Operating Voltage
19.00 ac volts minimum and 19.19 ac volts maximum single component all secondary
-
Terminal Type And Quantity
10 tab, solder lug
-
Thread Class
2b single group
-
Thread Direction
right-hand single group
-
Reliability Indicator
not established
-
Overall Length
2.750 inches maximum
-
Overall Width
2.000 inches maximum
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.375 inches nominal single mounting facility single center group
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.375 inches nominal single mounting facility single center group