CXA2137
Relays and Solenoids
RELAY,ELECTROMAGNETIC
CXA2137
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Facility Type And Quantity
4 unthreaded hole single mounting facility
-
Mounting Facility Pattern
rectangular single mounting facility
-
Nonpile-Up Main Contact Arrangement
2 pole, double throw, one position momentary
-
Main Contact Maximum Voltage Rating In Volts
230.0 ac and 115.0 dc
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.469 inches nominal single mounting facility
-
Winding Quantity
1
-
Overall Length
2.750 inches nominal
-
Overall Height
1.870 inches nominal
-
Unthreaded Mounting Hole Diameter
0.157 inches nominal single mounting facility
-
Terminal Type And Quantity
8 pin all functions
-
Main Contact Load Current Rating At Maximum Rated Voltage
3.0 amperes ac resistive load and 500.0 milliamperes dc resistive load
-
Coil Quantity
1
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.344 inches nominal single mounting facility
-
Operating Voltage Rating And Type At Specified Temp
4.0 volts teardrop, two holes type 4f single winding
-
Winding Dc Resistance Rating
10.5 ohms nominal single winding
-
Duty Type
continuous
-
Overall Width
1.870 inches nominal