3X1163SVHKMG4-50AMP250V400C2

Circuit Breakers

CIRCUIT BREAKER

3X1163SVHKMG4-50AMP250V400C2

5925-00-236-5274

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Switch Terminal Type

    tab, solder lug

  • Switch Current Rating And Type In Amps

    15.0 ac and 0.25 dc

  • Pole Quantity

    3

  • Circuit Protection Type

    overcurrent all locations

  • Maximum Continuous Load Current Rating Per Pole

    50.0 amperes ac all locations

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Mounting Facility Type And Quantity

    12 threaded hole and 12 unthreaded hole

  • Boss Height

    0.208 inches minimum and 0.228 inches maximum

  • Storage Type

    general purpose warehouse

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    3.052 inches minimum and 3.072 inches maximum

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

  • Body Height

    2.677 inches minimum and 2.697 inches maximum

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic-hydraulic all locations

  • Body Style

    multipole-multiple actuator type

  • Switch Contact Arrangement

    single pole, double throw

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Center To Center Distance Between Terminals Parallel To Width

    0.990 inches minimum and 1.010 inches maximum

  • Terminal Type And Quantity

    6 compression

  • Inclosure Protection Type For Which Designed

    dustproof and fungus proof

  • Body Width

    4.490 inches minimum and 4.510 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Nominal Thread Size

    0.164 inches

  • Center To Center Distance Between Terminals Parallel To Length

    4.349 inches minimum and 4.369 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.990 inches minimum and 1.010 inches maximum

  • Frequency In Hertz

    400.0 all locations

  • Body Length

    5.240 inches minimum and 5.260 inches maximum

  • Unthreaded Mounting Hole Diameter

    0.190 inches nominal

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Manual Actuator Type And Quantity

    3 toggle

  • Trip Delay Time In Seconds Per Rated Continuous Current

    5.500 minimum at 200 pct all locations and 20.000 maximum at 200 pct all locations

  • Switch Voltage Rating And Type In Volts

    460.0 ac and 250.0 dc

  • Switch Location And Position Designation

    internal at pole one

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...