6752-302-7 1/2

Circuit Breakers

CIRCUIT BREAKER

6752-302-7 1/2

5925-00-237-2170

5925 - Circuit Breakers

Sensata Technologies Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Maximum Continuous Load Current Rating Per Pole

    7.5 amperes ac and 7.5 amperes dc all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    thermal-magnetic all locations

  • Trip Release Characteristic

    time delay all locations

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Position Designation

    at pole two

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Switch Location And Position Designation

    internal at pole three

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Switch Terminal Type

    wire lead

  • Switch Current Rating And Type In Amps

    7.0 dc

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    6 tab w/screw

  • Body Width

    2.250 inches maximum

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.782 inches minimum and 1.842 inches maximum

  • Switch Contact Arrangement

    single pole, double throw

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.720 inches minimum and 0.780 inches maximum

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Iii Special Handling Feature

    magnetic

  • Operating Voltage Type And Rating Per Pole In Volts

    205.0 ac and 50.0 dc all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    4200.0 ac and 4200.0 dc all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 all locations

  • Manual Actuator Type And Quantity

    1 push-pull

  • Actuator Function

    trip-reset

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    14.000 minimum at 200 pct and 42.000 maximum at 200 pct all locations

  • Trip Release Ambient Temp Rating

    40.0 deg celsius maximum all locations

  • Switch Voltage Rating And Type In Volts

    28.0 dc

  • Frequency In Hertz

    400.0 all locations

  • Iii Unpackaged Unit Weight

    0.700 pounds

  • Body Style

    4b multipole-single actuator type

  • Bushing Length

    0.235 inches minimum and 0.250 inches maximum

  • Body Length

    2.189 inches maximum

  • Body Height

    2.440 inches minimum and 2.500 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.158 inches minimum and 1.218 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.720 inches minimum and 0.780 inches maximum

  • Iii Fragility Factor

    moderately rugged

  • Iii Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...