0411CSM6-6-5

Circuit Breakers

CIRCUIT BREAKER

0411CSM6-6-5

5925-00-240-3424

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Internal Trip Release Configuration

    series trip single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Pole Quantity

    1

  • Maximum Continuous Load Current Rating Per Pole

    6.5 amperes ac single location

  • Center To Center Distance Between Terminals Parallel To Length

    4.303 inches minimum and 4.323 inches maximum

  • Body Height

    2.600 inches minimum and 2.620 inches maximum

  • Body Length

    4.740 inches minimum and 4.760 inches maximum

  • Circuit Protection Type

    overcurrent single location

  • Thread Quantity Per Inch

    32

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.350 minimum at 200 pct single location and 1.000 maximum at 200 pct single location

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Reset Method

    manual

  • Thread Series Designator

    unc

  • Inclosure Protection Type For Which Designed

    dustproof

  • Fragility Factor

    moderately rugged

  • Case Material

    plastic

  • Operating Voltage Type And Rating Per Pole In Volts

    230.0 ac single location

  • Body Width

    1.015 inches minimum and 1.035 inches maximum

  • Frequency In Hertz

    60.0 single location

  • Trip Release Method

    magnetic-hydraulic single location

  • Mounting Facility Type And Quantity

    2 threaded hole and 1 unthreaded hole

  • Body Style

    single pole type

  • Terminal Type And Quantity

    1 tab w/screw and 1 screw

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.740 inches minimum and 2.760 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Trip Release Characteristic

    time delay single location

  • Unthreaded Mounting Hole Diameter

    0.164 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac single location

  • Nominal Thread Size

    0.138 inches

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...