7002289

Circuit Breakers

CIRCUIT BREAKER

7002289

5925-00-241-9773

5925 - Circuit Breakers

U S Army Tank Automotive Command

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Internal Trip Release Configuration

    series trip single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    20.000 minimum at 200 pct single location and 150.000 maximum at 200 pct single location

  • Mounting Facility Type And Quantity

    2 unthreaded hole

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Release Ambient Temp Rating

    77.0 deg fahrenheit nominal single location

  • Frequency In Hertz

    400.0 single location

  • Body Style

    single pole type

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac single location and 30.0 dc single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Unthreaded Mounting Hole Diameter

    0.190 inches nominal

  • Actuator Function

    reset

  • Fragility Factor

    moderately rugged

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Storage Type

    general purpose warehouse

  • Body Width

    1.250 inches nominal

  • Manual Actuator Type And Quantity

    1 push button

  • Terminal Type And Quantity

    2 screw

  • Center To Center Distance Between Terminals Parallel To Length

    0.453 inches nominal

  • Inclosure Protection Type For Which Designed

    shockproof

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Arc Quenching Method

    air

  • Mounting Surface To Terminal End Distance

    1.266 inches nominal

  • Unpackaged Unit Weight

    5.000 ounces

  • Pole Quantity

    1

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.574 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    875.0 ac single location and 875.0 dc single location

  • Maximum Continuous Load Current Rating Per Pole

    80.0 amperes ac single location and 80.0 amperes dc single location

  • Overall Length

    2.000 inches nominal

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...