ST28343
Coils and Transformers
TRANSFORMER,POWER
ST28343
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Winding Operating Voltage
107.00 ac volts nominal single component single primary and 115.00 ac volts nominal single component single primary and 123.00 ac volts nominal single component single primary
-
Reliability Indicator
not established
-
Winding Operating Current
15.0 amperes ac maximum single component single secondary
-
Input-Output Phase Relationship
single phase to single phase single component
-
Frequency Rating
60.0 hertz nominal single component
-
Mounting Facility Quantity
4 single group
-
Terminal Type And Quantity
4 standoff, solder lug
-
Body Width
3.562 inches nominal
-
Winding Operating Voltage
5.10 ac volts nominal single component single secondary
-
Body Length
4.188 inches nominal
-
Inclosure Type
fully inclosed
-
Winding Function And Quantity
1 primary single component and 1 secondary single component
-
Winding Shielding Method
internal shield grounded to inclosure single component
-
Body Height
4.500 inches nominal
-
Center To Center Distance Between Mounting Facilities Parallel To Length
3.125 inches nominal single mounting facility single center group
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.125 inches nominal single mounting facility single center group
-
Mounting Method
unthreaded stud single group