CF3-G3-U-90-240-1

Circuit Breakers

CIRCUIT BREAKER

CF3-G3-U-90-240-1

5925-00-243-8302

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Width

    1.032 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.032 inches nominal

  • Fragility Factor

    moderately rugged

  • Boss Height

    0.218 inches nominal

  • Mounting Surface To Terminal End Distance

    2.609 inches nominal

  • Pole Quantity

    3

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    6 threaded hole and 6 slot

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Trip Release Characteristic

    time delay all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Nominal Thread Size

    0.138 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    20.000 minimum at 200 pct and 105.000 maximum at 200 pct all locations

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Frequency In Hertz

    60.0

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    6 screw

  • Body Style

    8c multipole-multiple actuator type

  • Mounting Slot Width

    0.164 inches nominal

  • Body Length

    5.844 inches nominal

  • Body Width

    3.096 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    3.546 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Special Handling Feature

    magnetic

  • Maximum Continuous Load Current Rating Per Pole

    90.0 amperes ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    10000.0 ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    3 toggle

  • Actuator Position Designation

    at each pole

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Unpackaged Unit Weight

    2.000 pounds

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...