Technical Characteristics

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    300.0 ac all locations

  • Terminal Type And Quantity

    6 wire hook

  • Inclosure Protection Type For Which Designed

    shock resistant and hermetically sealed and vibration resistant and salt spray proof

  • Thread Series Designator

    unef

  • Frequency In Hertz

    400.0 all locations

  • Bushing Length

    0.365 inches minimum and 0.390 inches maximum

  • Body Length

    1.562 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    230.0 ac all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Body Width

    1.937 inches maximum

  • Manual Actuator Type And Quantity

    1 toggle

  • Center To Center Distance Between Terminals Parallel To Length

    0.865 inches minimum and 0.885 inches maximum

  • Case Material

    metal

  • Body Style

    multipole-single actuator type

  • Maximum Continuous Load Current Rating Per Pole

    3.0 amperes ac all locations

  • Actuator Position Designation

    at pole two

  • Mounting Surface To Terminal End Distance

    1.780 inches maximum

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Trip Release Method

    magnetic-hydraulic all locations

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.375 inches

  • Center To Center Distance Between Terminals Parallel To Width

    0.594 inches nominal and 0.656 inches maximum

  • Internal Trip Release Configuration

    series trip all locations

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Storage Type

    general purpose warehouse

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.850 minimum at 200 pct all locations and 4.000 maximum at 200 pct all locations

  • Reset Method

    manual

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

  • Special Handling Feature

    magnetic

  • Fragility Factor

    moderately rugged

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...