Technical Characteristics

  • Body Style

    2a single pole type

  • Center To Center Distance Between Terminals Parallel To Length

    0.906 inches maximum

  • Mounting Surface To Terminal End Distance

    1.700 inches maximum

  • Iii Arc Quenching Method

    magnetic blowout

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 dc single location

  • Circuit Protection Type

    overcurrent single location

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Internal Trip Release Configuration

    series trip single location

  • Inclosure Protection Type For Which Designed

    fungus resistant and hermetically sealed

  • Definitive Government Spec/Std Reference

    m39019/01-12

  • Test Data Document

    81349-mil-c-39019 specification

  • Thread Pitch Diameters

    0.3503 to 0.3537 inches

  • Bushing Length

    0.332 inches minimum and 0.380 inches maximum

  • Body Length

    1.562 inches maximum

  • Body Width

    0.625 inches maximum

  • Case Material

    metal

  • Iii Fragility Factor

    moderately rugged

  • Pole Quantity

    1

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Iii Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    500.0 milliamperes dc single location

  • Operating Voltage Type And Rating Per Pole In Volts

    50.0 dc single location

  • Trip Release Method

    magnetic single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Nominal Thread Size

    0.375 inches

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.500 minimum at 200 pct and 9.000 maximum at 200 pct and 1.750 maximum at 400 pct single location

  • Manufacturers Code

    81349

  • Non-Definitive Government Spec/Std Reference

    mil-c-39019/1

  • Thread Series Designator

    unef

  • Terminal Type And Quantity

    2 wire hook

  • Specification/Standard Data

    81349-mil-c-39019/1 government specification

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...