5925002472076

Circuit Breakers

CIRCUIT BREAKER

5925002472076

5925-00-247-2076

5925 - Circuit Breakers

E.c.a Etablissement Central Des

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Delay Time In Seconds Per Rated Continuous Current

    8.000 minimum at 200 pct single location and 50.000 maximum at 200 pct single location

  • Storage Type

    general purpose warehouse

  • Overall Length

    3.160 inches nominal

  • Specification/Standard Data

    81349--13516/7bii government specification

  • Mounting Surface To Terminal End Distance

    2.000 inches maximum

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.406 inches nominal

  • Pole Quantity

    1

  • Body Width

    1.880 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    575.0 dc single location

  • Maximum Continuous Load Current Rating Per Pole

    60.0 amperes dc single location

  • ~1

    data on certain environmental and performanc

  • Test Data Document

    81349-mil-c-13516 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Fragility Factor

    moderately rugged

  • Operating Voltage Type And Rating Per Pole In Volts

    28.0 dc single location

  • Internal Trip Release Configuration

    series trip single location

  • Mounting Facility Type And Quantity

    2 unthreaded hole

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Unthreaded Mounting Hole Diameter

    0.195 inches minimum and 0.225 inches maximum

  • Body Style

    single pole type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Center To Center Distance Between Terminals Parallel To Length

    1.060 inches nominal

  • Inclosure Protection Type For Which Designed

    shock resistant and salt spray proof and vibration resistant and fungus resistant

  • Reset Method

    automatic

  • Case Material

    plastic

  • Terminal Type And Quantity

    2 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...