2XAM1516MG3-15-250-2-50

Circuit Breakers

CIRCUIT BREAKER

2XAM1516MG3-15-250-2-50

5925-00-247-3001

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    2

  • Thread Series Designator

    unc

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Body Length

    3.719 inches nominal

  • Ultimate Trip Time Per Pole In Seconds

    10.000 minimum all locations and 80.000 maximum all locations

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip all locations

  • Center To Center Distance Between Terminals Parallel To Width

    1.031 inches nominal

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic-hydraulic all locations

  • Body Width

    2.031 inches nominal

  • Body Style

    multipole-multiple actuator type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Center To Center Distance Between Terminals Parallel To Length

    3.063 inches nominal

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Nominal Thread Size

    0.138 inches

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Manual Actuator Type And Quantity

    2 toggle

  • Trip Delay Time In Seconds Per Rated Continuous Current

    13.000 minimum at 150 pct all locations and 40.000 maximum at 150 pct all locations and 1.000 minimum at 400 pct all locations and 3.000 maximum at 400 pct all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.750 inches nominal

  • Terminal Type And Quantity

    4 threaded stud

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    1.031 inches nominal

  • External Actuator Linkage Arrangement

    one and two linked

  • Mounting Surface To Terminal End Distance

    3.427 inches nominal

  • Case Material

    plastic

  • Boss Height

    0.156 inches nominal

  • Frequency In Hertz

    50.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1500.0 ac all locations

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...