1885260-17
Circuit Breakers
CIRCUIT BREAKER
1885260-17
L-3 Communications Corporation
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Trip Delay Time In Seconds Per Rated Continuous Current
80.000 maximum at 200 pct single location and 20.000 minimum at 200 pct single location and 500.000 maximum at 150 pct single location and 6.000 minimum at 300 pct single location and 70.000 minimum at 150 pct single location and 20.000 maximum at 300 pct
-
Thread Series Designator
unc
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.812 inches nominal
-
Reset Method
manual
-
Actuator Position Designation
at pole one
-
Maximum Continuous Load Current Rating Per Pole
30.0 amperes ac single location and 30.0 amperes dc single location
-
Special Features
refinish mtg face plate the sides and top surface of the handle bezel
-
Actuator Function
trip-reset
-
Terminal Type And Quantity
2 screw
-
Mounting Facility Type And Quantity
2 threaded hole
-
Thread Quantity Per Inch
32
-
Mounting Surface To Terminal End Distance
2.000 inches maximum
-
Circuit Protection Type
overcurrent single location
-
Center To Center Distance Between Terminals Parallel To Length
1.188 inches nominal
-
Trip Release Method
thermal single location
-
Pole Quantity
1
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3000.0 ac single location and 5000.0 dc single location
-
Manual Actuator Type And Quantity
1 toggle
-
Body Length
2.189 inches maximum
-
Internal Trip Release Configuration
series trip single location
-
Nominal Thread Size
0.138 inches
-
Body Width
0.500 inches maximum
-
Trip Release Characteristic
time delay single location
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
-
Main Contact Tripping Mechanism Type
trip free
-
Frequency In Hertz
400.0 single location
-
Body Style
single pole type
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
-
Ultimate Trip Time Per Pole In Seconds
300.000 minimum single location
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location and 32.0 dc single location
-
Case Material
plastic
-
~1
single location