8151
Switches
SWITCH,THERMOSTATIC
8151
SWITCH,THERMOSTATIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Contact Adjustment Range
+36.00/+60.00 actuation point degrees fahrenheit and +36.00/+60.00 deactuation point degrees fahrenheit
-
Media For Which Designed
gas or liquid
-
Unthreaded Mounting Hole Diameter
0.185 inches nominal
-
Contact Load Current Rating
3.7 amperes resistive load first voltage
-
Contact Voltage Rating In Volts
115.0 ac at sea level second voltage
-
Hazardous Locations/Environmental Protection
dustproof
-
Features Provided
automatic reset
-
Overall Width
1.938 inches maximum
-
Mounting Facility Pattern
two position in-line
-
Bulb Diameter
0.375 inches nominal
-
Contact Action Stimulus
increase
-
Distance Between Mounting Facility Centers
2.187 inches nominal
-
Temp Sensing Element Type
capillary tube-bulb
-
Contact Adjustability
deactuation point adjustable and actuation point adjustable
-
Mounting Method
bracket and unthreaded hole
-
Contact Voltage Rating In Volts
230.0 ac at sea level first voltage
-
Contact Load Current Rating
7.4 amperes resistive load second voltage
-
Overall Length
3.375 inches nominal
-
Criticality Code Justification
feat
-
Contact Adjustment Type
external deactuation point shaft and external actuation point shaft
-
Special Features
weapon system essential
-
Capillary Tube Length
48.0 inches nominal
-
Overall Height
3.156 inches nominal
-
Nonpile-Up Contact Arrangement
1 pole, single throw, normally open, momentary action
-
Contact Voltage Rating In Volts
115.0 dc at sea level third voltage
-
Terminal Type
tab, solder lug
-
Contact Load Current Rating
2.4 amperes resistive load third voltage
-
Style Designator
rectangular
-
Bulb Length
1.500 inches nominal