MIL-R-6106
Relays and Solenoids
RELAY,ELECTROMAGNETIC
MIL-R-6106
RELAY,ELECTROMAGNETIC
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Main Contact Load Current Rating At Maximum Rated Voltage
3.0 amperes ac inductive load and 3.0 amperes dc inductive load
-
Fragility Factor
moderately rugged
-
Main Contact Load Current Rating At Maximum Rated Voltage
800.0 milliamperes ac lamp load and 800.0 milliamperes dc lamp load
-
Nonpile-Up Main Contact Arrangement
6 pole, double throw, one position momentary
-
Mounting Facility Type And Quantity
3 unthreaded hole single mounting facility
-
Storage Type
general purpose warehouse
-
Main Contact Load Current Rating At Maximum Rated Voltage
5.0 amperes ac resistive load and 5.0 amperes dc resistive load
-
Precious Material
gold
-
Precious Material And Location
terminal surfaces gold
-
Environmental Protection
hermetic
-
Overall Width
1.562 inches maximum
-
Arc Quenching Method
air
-
Center To Center Distance Between Mounting Facilities Parallel To Width
0.750 inches nominal single mounting facility
-
Unthreaded Mounting Hole Diameter
0.147 inches nominal single mounting facility
-
Case Material
metal
-
Winding Quantity
2
-
Operating Voltage Rating And Type At Specified Temp
28.0 volts dc 25 deg celsius all windings
-
Mounting Facility Pattern
triangle single mounting facility
-
Center To Center Distance Between Mounting Facilities Parallel To The Altitude Of An Isosceles Triangle
1.844 inches nominal single mounting facility
-
Main Contact Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
-
Specification/Standard Data
96906-ms25463 government standard
-
Cubic Measure
7.365 cubic inches
-
Coil Quantity
2
-
Purpose For Which Designed
general
-
Overall Height
2.156 inches nominal
-
Overall Length
2.187 inches maximum
-
Features Provided
latching contacts
-
Terminal Type And Quantity
22 pin all functions
-
Main Contact Load Current Rating At Maximum Rated Voltage
1.5 amperes ac motor load and 1.5 amperes dc motor load
-
Time Delay
0.025 seconds maximum fixed operate time
-
Duty Type
continuous
-
~1
data on certain environmental and performance
-
Test Data Document
81349-mil-r-6106 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type