105-240-101

Circuit Breakers

CIRCUIT BREAKER

105-240-101

5925-00-252-4265

5925 - Circuit Breakers

Wood Electric Operations Potter And

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Manual Actuator Type And Quantity

    1 push-pull

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Internal Trip Release Configuration

    series trip single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    20.000 minimum at 200 pct and 120.000 maximum at 200 pct single location

  • Frequency In Hertz

    400.0

  • Unpackaged Unit Weight

    0.100 pounds

  • Thread Series Designator

    uns

  • Terminal Type And Quantity

    2 tab w/screw

  • Reset Method

    manual

  • Trip Release Characteristic

    time delay single location

  • Trip Release Method

    thermal single location

  • Maximum Continuous Load Current Rating Per Pole

    40.0 amperes ac and 40.0 amperes dc single location

  • Storage Type

    general purpose warehouse

  • Mounting Facility Type And Quantity

    1 threaded bushing w/panel seal

  • Body Style

    1a single pole type

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Inclosure Protection Type For Which Designed

    humidity resistant and salt spray proof and shock resistant and vibration resistant

  • Nominal Thread Size

    0.469 inches

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0

  • Circuit Protection Type

    overcurrent single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    3000.0 ac and 5000.0 dc single location

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac and 32.0 dc single location

  • Thread Quantity Per Inch

    32

  • Pole Quantity

    1

  • Mounting Surface To Terminal End Distance

    1.810 inches maximum

  • Fragility Factor

    moderately rugged

  • Center To Center Distance Between Terminals Parallel To Length

    0.690 inches minimum and 0.710 inches maximum

  • Case Material

    plastic

  • Body Width

    0.750 inches maximum

  • Body Length

    1.090 inches maximum

  • Bushing Length

    0.235 inches minimum and 0.255 inches maximum

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...