Technical Characteristics
-
Contact Adjustability
deactuation point not adjustable and actuation point not adjustable
-
Mounting Facility Pattern
two position in-line
-
Contact Action Stimulus
increase
-
Distance Between Mounting Facility Centers
0.422 inches minimum and 0.452 inches maximum
-
Unthreaded Mounting Hole Diameter
0.147 inches nominal
-
Mounting Method
bracket and unthreaded hole
-
Body Diameter
0.560 inches nominal
-
Style Designator
disc w/flange
-
Overall Length
0.875 inches maximum
-
Contact Stimulus Rating
167.00 actuation point minimum degrees fahrenheit and 171.00 actuation point maximum degrees fahrenheit and 2.00 differential point minimum degrees fahrenheit and 6.00 differential point maximum degrees fahrenheit
-
Contact Voltage Rating In Volts
120.0 ac at sea level first voltage
-
Terminal Type
tab, solder lug
-
Operating Temp Rating
-65.0 deg fahrenheit minimum and 300.0 deg fahrenheit maximum
-
Temp Sensing Element Type
internal sensor
-
Contact Load Current Rating
3.0 amperes resistive load second voltage
-
Media For Which Designed
gas or liquid
-
Contact Load Current Rating
3.0 amperes resistive load first voltage
-
Overall Height
0.261 inches minimum and 0.301 inches maximum
-
Frequency In Hertz
60.0 first voltage
-
Nonpile-Up Contact Arrangement
1 pole, single throw, normally closed, momentary action
-
Body Height
0.172 inches minimum and 0.202 inches maximum
-
Contact Voltage Rating In Volts
28.0 dc at sea level second voltage