662-0503-010
Coils and Transformers
TRANSFORMER,POWER
662-0503-010
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Facility Quantity
4 single group
-
Body Height
3.000 inches maximum
-
Winding Shielding Method
internal shield grounded to inclosure and core single component
-
Body Length
3.500 inches maximum
-
Winding Operating Current
500.0 milliamperes dc maximum single component 2nd secondary
-
Winding Operating Current
500.0 milliamperes dc maximum single component 3rd secondary
-
Mounting Slot Width
0.203 inches nominal single group
-
Inclosure Type
fully inclosed
-
Body Width
3.125 inches maximum
-
Frequency Rating
47.0 hertz minimum single component and 63.0 hertz maximum single component
-
Reliability Indicator
not established
-
Input-Output Phase Relationship
single phase to single phase single component
-
Winding Function And Quantity
2 primary single component and 3 secondary single component
-
Winding Operating Voltage
115.00 ac volts nominal single component all primary
-
Winding Operating Current
2.5 amperes dc maximum single component 1st secondary
-
Mounting Method
flange single group and slot single group
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.500 inches nominal single mounting facility single center group
-
Terminal Type And Quantity
13 tab, solder lug
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.813 inches nominal single mounting facility single center group