K43J227
Coils and Transformers
TRANSFORMER,POWER
K43J227
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Facility Quantity
4 single group
-
Overall Height
6.031 inches nominal
-
Winding Operating Voltage
5.00 ac volts nominal single component 3rd secondary
-
Nominal Thread Size
0.190 inches single group
-
Terminal Type And Quantity
10 feed thru
-
Thread Series Designator
unc single group
-
Body Width
4.312 inches nominal
-
Winding Shielding Method
internal shield grounded to core single component
-
Thread Quantity Per Inch
24 single group
-
Frequency Rating
60.0 hertz nominal single component
-
Winding Operating Voltage
115.00 ac volts nominal single component single primary
-
Input-Output Phase Relationship
single phase to single phase single component
-
Winding Operating Voltage
5.00 ac volts nominal single component 2nd secondary
-
Winding Operating Voltage
5.00 ac volts nominal single component 1st secondary
-
Winding Operating Current
500.0 milliamperes ac maximum single component 4th secondary
-
Center To Center Distance Between Mounting Facilities Parallel To Width
3.188 inches nominal single mounting facility single center group
-
Reliability Indicator
not established
-
Winding Function And Quantity
1 primary single component and 4 secondary single component
-
Winding Operating Current
6.0 amperes ac maximum single component 2nd secondary
-
Mounting Method
threaded stud single group
-
Winding Operating Voltage
6.30 ac volts nominal single component 4th secondary
-
Body Length
4.875 inches nominal
-
Inclosure Type
open
-
Center To Center Distance Between Mounting Facilities Parallel To Length
4.250 inches nominal single mounting facility single center group
-
Body Height
5.281 inches nominal
-
Winding Operating Current
3.0 amperes ac maximum single component 3rd secondary
-
Winding Operating Current
12.0 amperes ac maximum single component 1st secondary
-
Maximum Operating Temp
60.0 deg celsius