6363-1-5

Circuit Breakers

CIRCUIT BREAKER

6363-1-5

5925-00-258-7121

5925 - Circuit Breakers

Sensata Technologies Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Fragility Factor

    moderately rugged

  • Center To Center Distance Between Terminals Parallel To Length

    0.750 inches nominal

  • Body Width

    0.766 inches nominal

  • Thread Series Designator

    unc

  • Body Length

    2.203 inches nominal

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    1.813 inches nominal

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    122.0 single location

  • Special Features

    luminous tip

  • Terminal Type And Quantity

    2 screw

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Arc Quenching Method

    air

  • Unpackaged Unit Weight

    1.850 ounces

  • Trip Delay Time In Seconds Per Rated Continuous Current

    50.000 nominal at 200 pct single location and 800.000 nominal at 125 pct single location and 12.000 nominal at 300 pct single location

  • Pole Quantity

    1

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac single location and 5.0 amperes dc single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Trip Release Characteristic

    time delay single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Nominal Thread Size

    0.164 inches

  • Operating Voltage Type And Rating Per Pole In Volts

    30.0 ac single location and 30.0 dc single location

  • Mounting Surface To Terminal End Distance

    1.438 inches nominal

  • Body Style

    single pole type

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    100.0 ac single location and 100.0 dc single location

  • Frequency In Hertz

    60.0 single location

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...