740058-2

Circuit Breakers

CIRCUIT BREAKER

740058-2

5925-00-265-2275

5925 - Circuit Breakers

L-3 Communications Cincinnati

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Pole Quantity

    3

  • Special Handling Feature

    magnetic

  • Fragility Factor

    moderately rugged

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac all locations

  • Internal Trip Release Configuration

    series trip all locations

  • Mounting Facility Type And Quantity

    4 threaded hole and 4 unthreaded hole

  • Actuator Function

    trip-reset

  • Trip Release Characteristic

    time delay all locations

  • Storage Type

    general purpose warehouse

  • Reset Method

    manual

  • Thread Series Designator

    unc

  • Inclosure Protection Type For Which Designed

    fungus resistant and general purpose and moisture resistant

  • Circuit Protection Type

    overcurrent all locations

  • Terminal Type And Quantity

    6 threaded stud

  • Unpackaged Unit Weight

    29.000 ounces

  • Body Length

    5.250 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    0.984 inches nominal

  • Thread Quantity Per Inch

    32

  • Trip Release Method

    magnetic-hydraulic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    3.063 inches nominal

  • Actuator Position Designation

    at pole two

  • Mounting Surface To Terminal End Distance

    3.177 inches minimum and 3.197 inches maximum

  • Body Style

    multipole-single actuator type

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.984 inches nominal

  • Body Width

    3.000 inches nominal

  • Manual Actuator Type And Quantity

    1 toggle

  • Frequency In Hertz

    60.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Arc Quenching Method

    magnetic blowout

  • Nominal Thread Size

    0.164 inches

  • Boss Height

    0.218 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac all locations

  • Body Height

    2.687 inches nominal

  • Operating Voltage Type And Rating Per Pole In Volts

    250.0 ac all locations

  • Center To Center Distance Between Terminals Parallel To Length

    4.359 inches nominal

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.320 minimum at 200 pct all locations and 0.950 maximum at 200 pct all locations

  • Unthreaded Mounting Hole Diameter

    0.190 inches nominal

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...