RRP112R891-2

Circuit Breakers

CIRCUIT BREAKER

RRP112R891-2

5925-00-267-1459

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Internal Trip Release Configuration

    series trip second location

  • Case Material

    metal

  • Switch Contact Arrangement

    single pole, double throw

  • Inclosure Protection Type For Which Designed

    hermetically sealed

  • Internal Trip Release Configuration

    series trip w/dual rating and remote trip feature first location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • Trip Release Method

    magnetic all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    500.0 ac all locations

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    4 threaded hole

  • Terminal Type And Quantity

    2 tab, solder lug and 6 wire hook

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac all locations

  • Reset Actuator Voltage Rating And Type In Volts

    29.0 dc

  • Trip Release Characteristic

    time delay all locations

  • Thread Series Designator

    unc

  • Switch Current Rating And Type In Amps

    1.0 dc

  • Body Style

    rectangular dimensional envelope

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

  • Switch Terminal Type

    tab, solder lug

  • Reset Method

    electric

  • Auxiliary Trip Coil Voltage Type And Rating In Volts

    29.0 dc maximum first location

  • Overall Height

    2.850 inches maximum

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.500 minimum at 200 pct all locations and 9.000 maximum at 200 pct all locations

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Frequency In Hertz

    400.0 all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac all locations

  • Switch Voltage Rating And Type In Volts

    28.0 dc

  • Trip Release Duty Cycle

    continuous all locations

  • Overall Width

    1.515 inches maximum

  • Main Contact Tripping Mechanism Type

    trip free

  • Internal Trip Release Configuration

    series trip third location

  • Nominal Thread Size

    0.138 inches

  • Overall Length

    2.190 inches maximum

  • Switch Location And Position Designation

    internal at pole one

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...