RRP112R891-2
Circuit Breakers
CIRCUIT BREAKER
RRP112R891-2
Sensata Technologies Maryland Inc
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Internal Trip Release Configuration
series trip second location
-
Case Material
metal
-
Switch Contact Arrangement
single pole, double throw
-
Inclosure Protection Type For Which Designed
hermetically sealed
-
Internal Trip Release Configuration
series trip w/dual rating and remote trip feature first location
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Trip Release Method
magnetic all locations
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 ac all locations
-
Thread Quantity Per Inch
32
-
Mounting Facility Type And Quantity
4 threaded hole
-
Terminal Type And Quantity
2 tab, solder lug and 6 wire hook
-
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac all locations
-
Reset Actuator Voltage Rating And Type In Volts
29.0 dc
-
Trip Release Characteristic
time delay all locations
-
Thread Series Designator
unc
-
Switch Current Rating And Type In Amps
1.0 dc
-
Body Style
rectangular dimensional envelope
-
Circuit Protection Type
overcurrent all locations
-
Pole Quantity
3
-
Switch Terminal Type
tab, solder lug
-
Reset Method
electric
-
Auxiliary Trip Coil Voltage Type And Rating In Volts
29.0 dc maximum first location
-
Overall Height
2.850 inches maximum
-
Trip Delay Time In Seconds Per Rated Continuous Current
0.500 minimum at 200 pct all locations and 9.000 maximum at 200 pct all locations
-
Auxiliary Switch Function And Quantity
1 alarm
-
Frequency In Hertz
400.0 all locations
-
Operating Voltage Type And Rating Per Pole In Volts
115.0 ac all locations
-
Switch Voltage Rating And Type In Volts
28.0 dc
-
Trip Release Duty Cycle
continuous all locations
-
Overall Width
1.515 inches maximum
-
Main Contact Tripping Mechanism Type
trip free
-
Internal Trip Release Configuration
series trip third location
-
Nominal Thread Size
0.138 inches
-
Overall Length
2.190 inches maximum
-
Switch Location And Position Designation
internal at pole one