309-10
Switches
SWITCH,PRESSURE
309-10
SWITCH,PRESSURE
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Method
inlet connection
-
Contact Voltage Rating In Volts
6.0 dc at sea level second voltage
-
Style Designator
cylindrical
-
Contact Stimulus Rating
5.50 actuation point nominal pounds per square inch and 6.50 deactuation point nominal pounds per square inch and 1.00 differential point nominal pounds per square inch
-
Thread Series Designator
npt single pressure connection
-
Proof Pressure
150.00 pounds per square inch
-
Special Features
mounts by means of 1/8-27 male pipe thd formed on neck
-
Overall Diameter
1.690 inches nominal
-
Terminal Type
tab w/screw
-
Nominal Thread Size
0.125 inches single pressure connection
-
Nonpile-Up Contact Arrangement
1 pole, single throw, normally open, momentary action
-
Contact Load Current Rating
15.0 amperes resistive load second voltage
-
Contact Voltage Rating In Volts
24.0 dc at sea level first voltage
-
Features Provided
pilot light
-
Outside Diameter
0.125 inches nominal single connection
-
Thread Quantity Per Inch
27 single pressure connection
-
Media For Which Designed
gas or liquid
-
Pressure Connector Type
plain, threaded external single connection
-
Contact Load Current Rating
4.0 amperes resistive load first voltage
-
Pressure Switch Type
gage
-
Contact Action Stimulus
decrease
-
Overall Length
2.000 inches nominal
-
Contact Adjustability
deactuation point not adjustable and actuation point not adjustable
-
Body Length
1.500 inches nominal