3H900-16

Circuit Breakers

CIRCUIT BREAKER

3H900-16

5925-00-272-6749

5925 - Circuit Breakers

Us Army Communications &

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    single pole type

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.928 inches minimum and 1.948 inches maximum

  • Fragility Factor

    moderately rugged

  • Circuit Protection Type

    overcurrent

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip

  • Nominal Thread Size

    0.138 inches

  • Frequency In Hertz

    60.0

  • Unpackaged Unit Weight

    4.750 ounces

  • Terminal Type And Quantity

    2 threaded stud

  • Body Length

    2.490 inches minimum and 2.510 inches maximum

  • Body Width

    0.740 inches minimum and 0.760 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.052 inches minimum and 2.072 inches maximum

  • Boss Height

    0.130 inches minimum and 0.150 inches maximum

  • Mounting Surface To Terminal End Distance

    2.549 inches minimum and 2.673 inches maximum

  • Pole Quantity

    1

  • Arc Quenching Method

    magnetic blowout

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    16.0 amperes ac

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 ac

  • Trip Release Method

    magnetic

  • Trip Release Characteristic

    time delay

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    3.500 minimum at 200 pct and 11.000 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Thread Series Designator

    unc

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...