C4524-1626-1

Switches

SWITCH,PRESSURE

C4524-1626-1

5930-00-275-7800

5930 - Switches

Trane U.s. Inc.

SWITCH,PRESSURE

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Contact Load Current Rating

    16.0 amperes resistive load third voltage

  • Pressure Switch Type

    gage

  • Overall Height

    1.125 inches maximum

  • Overall Length

    3.344 inches nominal

  • Contact Action Stimulus

    decrease

  • Pressure Connector Type

    shoulder, unthreaded external single connection

  • Mounting Facility Pattern

    two position in-line

  • Contact Stimulus Rating

    460.00 deactuation point nominal pounds per square inch gage and 415.00 actuation point nominal pounds per square inch gage and 45.00 differential point nominal pounds per square inch gage

  • Style Designator

    bourdon tube, open frame

  • End Item Identification

    agm-86b air launch cruise missle (alcm). 485l tacs. 36k btu amily air conditioner. an/tps-59 3d lightweight radar set. f18-mpi air conditioner. lav anti-tank. refridgeration systems. f-4 phantom aircraft. 30hz 1800btu air condtioner. 6000 btu air

  • ~1

    conditioner.

  • Body Length

    3.344 inches nominal

  • Contact Voltage Rating In Volts

    240.0 ac at sea level first voltage

  • Distance Between Mounting Facility Centers

    0.688 inches nominal

  • Precious Material

    silver

  • Criticality Code Justification

    feat

  • Sensing Element Burst Pressure

    1800.00 pounds per square inch gage

  • Special Features

    weapon system essential

  • Contact Adjustability

    deactuation point not adjustable, manual reset and actuation point not adjustable

  • Contact Load Current Rating

    9.2 amperes resistive load second voltage

  • Overall Width

    2.703 inches nominal

  • Inside Diameter

    0.250 inches nominal single connection

  • Outside Diameter

    0.375 inches nominal single connection

  • Contact Voltage Rating In Volts

    208.0 ac at sea level second voltage

  • Mounting Method

    flush and threaded hole

  • Terminal Type

    screw

  • Media For Which Designed

    gas or liquid

  • Contact Load Current Rating

    3.0 amperes resistive load first voltage

  • Contact Voltage Rating In Volts

    120.0 ac at sea level third voltage

  • Nonpile-Up Contact Arrangement

    1 pole, single throw, normally closed, momentary action

  • Features Provided

    electrical access port

  • Proof Pressure

    500.00 pounds per square inch gage

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...