9124-1Z-C7C4-002

Relays and Solenoids

RELAY,ELECTROMAGNETIC

9124-1Z-C7C4-002

5945-00-276-3183

5945 - Relays and Solenoids

Leach Corp

RELAY,ELECTROMAGNETIC

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Auxiliary Contact Load Current Rating At Maximum Rated Voltage

    1.0 amperes ac lamp load and 1.0 amperes dc lamp load

  • Main Contact Load Current Rating At Maximum Rated Voltage

    50.0 amperes ac inductive load and 50.0 amperes dc inductive load

  • Center To Center Distance Between Mounting Facilities Parallel To Width

    2.677 inches minimum single mounting facility and 2.697 inches maximum single mounting facility

  • Terminal Type And Quantity

    12 threaded stud all functions

  • Main Contact Maximum Voltage Rating In Volts

    200.0 ac and 28.0 dc

  • Purpose For Which Designed

    general

  • Operating Voltage Rating And Type At Specified Temp

    28.0 volts dc 25 deg celsius single winding

  • Overall Length

    3.668 inches minimum and 3.730 inches maximum

  • Coil Quantity

    1

  • Overall Width

    3.243 inches minimum and 3.305 inches maximum

  • Main Contact Load Current Rating At Maximum Rated Voltage

    50.0 amperes ac motor load and 50.0 amperes dc motor load

  • Winding Dc Resistance Rating

    50.0 ohms nominal single winding

  • Duty Type

    continuous

  • Unthreaded Mounting Hole Diameter

    0.187 inches minimum single mounting facility and 0.249 inches maximum single mounting facility

  • Contact Material

    metal

  • Nonpile-Up Main Contact Arrangement

    3 pole, single throw, normally open, double make, momentary action

  • Fragility Factor

    moderately rugged

  • Mounting Facility Type And Quantity

    4 unthreaded hole single mounting facility

  • Mounting Facility Pattern

    rectangular single mounting facility

  • Storage Type

    general purpose warehouse

  • Auxiliary Contact Load Current Rating At Maximum Rated Voltage

    5.0 amperes ac resistive load and 5.0 amperes dc resistive load

  • Environmental Protection

    hermetic

  • Auxiliary Contact Maximum Voltage Rating In Volts

    115.0 ac and 28.0 dc

  • Time Delay

    0.025 seconds nominal fixed operate time

  • Arc Quenching Method

    air

  • Cubic Measure

    38.203 cubic inches

  • Winding Quantity

    1

  • Overall Height

    2.344 inches minimum and 2.532 inches maximum

  • Center To Center Distance Between Mounting Facilities Parallel To Length

    3.240 inches minimum single mounting facility and 3.260 inches maximum single mounting facility

  • Main Contact Load Current Rating At Maximum Rated Voltage

    50.0 amperes ac resistive load and 50.0 amperes dc resistive load

  • Case Material

    metal

  • Nonpile-Up Auxiliary Contact Arrangement

    1 pole, single throw, normally open, double make, momentary action and 1 pole, single throw, normally closed, double break, momentary action

  • Auxiliary Contact Load Current Rating At Maximum Rated Voltage

    5.0 amperes ac inductive load and 5.0 amperes dc inductive load

  • Time Delay

    0.01 seconds nominal fixed release time

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...