454D507G02

Circuit Breakers

CIRCUIT BREAKER

454D507G02

5925-00-279-1351

5925 - Circuit Breakers

Eaton Corporation

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Length

    2.985 inches minimum and 3.015 inches maximum

  • Body Width

    1.000 inches maximum

  • Center To Center Distance Between Terminals Parallel To Length

    1.796 inches minimum and 1.828 inches maximum

  • Fragility Factor

    moderately rugged

  • Boss Height

    0.005 inches nominal

  • Mounting Surface To Terminal End Distance

    2.554 inches minimum and 2.624 inches maximum

  • Pole Quantity

    1

  • Arc Quenching Method

    deion

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Storage Type

    general purpose warehouse

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    10.0 amperes ac single location and 10.0 amperes dc

  • Operating Voltage Type And Rating Per Pole In Volts

    125.0 ac single location and 32.0 dc

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Characteristic

    time delay single location

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    122.0 single location

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    1 toggle

  • Actuator Position Designation

    at pole one

  • Trip Delay Time In Seconds Per Rated Continuous Current

    12.800 minimum at 200 pct single location and 38.000 maximum at 200 pct

  • Inclosure Protection Type For Which Designed

    general purpose

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Precious Material And Location

    contact surfaces silver

  • Precious Material

    silver

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    2 threaded stud

  • Body Style

    12a single pole type

  • Case Material

    plastic

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.625 inches nominal

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac single location and 5000.0 dc

  • Trip Release Method

    thermal single location

  • Ultimate Trip Time Per Pole In Seconds

    80.000 minimum single location and 3600.000 maximum

  • Actuator Function

    trip-reset

  • Internal Trip Release Configuration

    series trip single location

  • Nominal Thread Size

    0.164 inches

  • Frequency In Hertz

    60.0 single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...