6141H80
Circuit Breakers
CIRCUIT BREAKER
6141H80
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Reset Method
manual
-
Actuator Function
trip-reset
-
Maximum Continuous Load Current Rating Per Pole
33.0 amperes dc single location
-
Circuit Protection Type
overcurrent single location
-
Trip Delay Time In Seconds Per Rated Continuous Current
6.000 minimum at 200 pct single location and 60.000 maximum at 200 pct single location
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 dc single location
-
Trip Release Method
thermal single location
-
Pole Quantity
1
-
Internal Trip Release Configuration
series trip w/dual rating and remote trip feature single location
-
Mounting Facility Type And Quantity
2 unthreaded hole
-
Trip Release Characteristic
time delay single location
-
Trip Release Ambient Temp Rating
25.0 deg celsius nominal single location
-
Main Contact Tripping Mechanism Type
trip free
-
Unthreaded Mounting Hole Diameter
0.203 inches nominal
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 single location
-
Operating Voltage Type And Rating Per Pole In Volts
24.0 dc single location
-
Terminal Type And Quantity
4 threaded stud
-
Case Material
plastic