SM33HK10-400-1
Circuit Breakers
CIRCUIT BREAKER
SM33HK10-400-1
CIRCUIT BREAKER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Auxiliary Switch Function And Quantity
1 control
-
Fragility Factor
moderately rugged
-
Switch Terminal Type
tab, solder lug
-
Special Handling Feature
magnetic
-
Circuit Protection Type
overcurrent all locations
-
Pole Quantity
2
-
Reset Method
manual
-
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal
-
Storage Type
general purpose warehouse
-
Trip Release Characteristic
time delay all locations
-
Center To Center Distance Between Terminals Parallel To Width
0.625 inches nominal
-
Actuator Function
trip-reset
-
Internal Trip Release Configuration
series trip all locations
-
Switch Voltage Rating And Type In Volts
125.0 ac and 50.0 dc
-
Nominal Thread Size
0.375 inches
-
Thread Quantity Per Inch
32
-
Trip Release Method
magnetic-hydraulic all locations
-
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
-
Mounting Surface To Terminal End Distance
1.780 inches maximum
-
Inclosure Protection Type For Which Designed
hermetically sealed
-
Terminal Type And Quantity
4 wire hook
-
Switch Contact Arrangement
single pole, double throw
-
Center To Center Distance Between Terminals Parallel To Length
0.875 inches nominal
-
Bushing Length
0.375 inches maximum
-
Body Style
multipole-single actuator type
-
Case Material
metal
-
Ultimate Trip Time Per Pole In Seconds
6.000 minimum all locations and 30.000 maximum all locations
-
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac all locations
-
Trip Delay Time In Seconds Per Rated Continuous Current
15.000 maximum at 150 pct all locations and 0.020 minimum at 400 pct all locations and 3.000 minimum at 150 pct all locations and 0.100 maximum at 400 pct all locations
-
Manual Actuator Type And Quantity
1 toggle
-
Body Length
1.500 inches maximum
-
Actuator Position Designation
between pole one and two
-
Main Contact Tripping Mechanism Type
trip free
-
Arc Quenching Method
magnetic blowout
-
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
-
Body Width
1.250 inches maximum
-
Frequency In Hertz
400.0 all locations
-
Thread Series Designator
unef
-
Switch Current Rating And Type In Amps
1.0 ac and 0.5 dc
-
Switch Location And Position Designation
internal at pole one
-
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac all locations