Operating Temp Range
+0.0/+65.0 deg celsius
-
Discrimination At Specified Frequencies Per Function In Decibels
3.0 maximum 1st band pass and 60.0 minimum 1st band pass and 3.0 maximum 1st band pass and 60.0 minimum 1st band pass
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.250 inches nominal
-
Mounting Facility Type And Quantity
4 threaded stud
-
Specified Frequencies Of Discrimination Per Function
30.50 megahertz 1st band pass and 10.00 megahertz 1st band pass and 30.94 megahertz 1st band pass and 80.00 megahertz 1st band pass
-
Output Impedance Per Function W/Source Across Input
50.0 ohms 3rd band pass
-
Specified Frequencies Of Discrimination Per Function
10.00 megahertz 3rd band pass and 30.50 megahertz 3rd band pass and 30.94 megahertz 3rd band pass and 80.00 megahertz 3rd band pass
-
Input Impedance Per Function W/Load
50.0 ohms 3rd band pass
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
3.000 inches nominal
-
Frequency Band Width Per Function
30.50 megahertz 3rd band pass and 30.94 megahertz 3rd band pass
-
Functional Terminal Type And Quantity
3 connector, receptacle input 1st function
-
Discrimination At Specified Frequencies Per Function In Decibels
3.0 maximum 3rd band pass and 3.0 maximum 3rd band pass and 60.0 minimum 3rd band pass and 60.0 minimum 3rd band pass
-
Nominal Thread Size
0.112 inches
-
Mounting Facility Screw Thread Series Designator
unc
-
Frequency Band Width Per Function
30.50 megahertz 2nd band pass and 30.94 megahertz 2nd band pass
-
Input Impedance Per Function W/Load
50.0 ohms 2nd band pass
-
Discrimination At Specified Frequencies Per Function In Decibels
60.0 minimum 2nd band pass and 3.0 maximum 2nd band pass and 3.0 maximum 2nd band pass and 60.0 minimum 2nd band pass
-
Output Impedance Per Function W/Source Across Input
50.0 ohms 2nd band pass
-
Body Length
3.500 inches nominal
-
Body Height
1.750 inches nominal
-
Insertion Loss At Reference Frequency Per Function In Decibels
2.5 3rd band pass
-
Vibration Resistance Range In Hertz
+10.0/+55.0
-
Insertion Loss At Reference Frequency Per Function In Decibels
2.5 2nd band pass
-
Frequency Band Width Per Function
30.50 megahertz 1st band pass and 30.94 megahertz 1st band pass
-
Input Impedance Per Function W/Load
50.0 ohms 1st band pass
-
Insertion Loss At Reference Frequency Per Function In Decibels
2.5 1st band pass
-
Overall Height
2.125 inches nominal
-
Reference Frequency Per Function
30.7465 hercules no.5599.1 two phase to two phase
-
Style Designator
rectangular terminal/terminals on one surface
-
Output Impedance Per Function W/Source Across Input
50.0 ohms 1st band pass
-
Body Material
metal
-
Reference Frequency Per Function
30.7465 hercules no.5599.1 two phase to three phase
-
Specified Frequencies Of Discrimination Per Function
30.50 megahertz 2nd band pass and 10.00 megahertz 2nd band pass and 30.94 megahertz 2nd band pass and 80.00 megahertz 2nd band pass
-
Principal Circuitry Type Per Function
inductance-capacitance blank
-
Reference Frequency Per Function
30.7465 hercules no.5599.1 pulses per second
-
Inclosure Type
encased
-
Functional Terminal Type And Quantity
6 connector, receptacle output 2nd function