SM-C-97119
Coils and Transformers
TRANSFORMER,POWER
SM-C-97119
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Facility Quantity
4 single group
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.000 inches nominal single mounting facility single center group
-
Body Length
2.188 inches maximum
-
Winding Operating Current
13.8 milliamperes ac maximum single component single primary
-
Center To Center Distance Between Mounting Facilities Parallel To Length
1.312 inches nominal single mounting facility single center group
-
Frequency Rating
50.0 hertz minimum single component and 60.0 hertz maximum single component
-
Winding Operating Current
600.0 milliamperes ac nominal single component single secondary
-
Winding Power Rating
5.5 volts-amperes single component single secondary
-
Mounting Method
threaded stud single group
-
Body Height
3.062 inches maximum
-
Winding Operating Voltage
117.00 ac volts nominal single component single primary
-
Reliability Indicator
not established
-
Input-Output Phase Relationship
single phase to single phase single component
-
Inclosure Type
hermetically sealed
-
Winding Power Rating
7.0 watts single component single primary
-
Winding Function And Quantity
1 primary single component and 1 secondary single component
-
Body Width
2.166 inches maximum
-
Winding Operating Voltage
9.20 ac volts nominal single component single secondary
-
Maximum Operating Temp
105.0 deg celsius
-
Terminal Type And Quantity
4 solder stud