6676
Coils and Transformers
TRANSFORMER,POWER
6676
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Reliability Indicator
not established
-
Mounting Slot Width
0.219 inches nominal single group
-
Input-Output Phase Relationship
single phase to single phase single component
-
Winding Shielding Method
internal shield grounded to inclosure single component
-
Body Length
3.875 inches maximum
-
Body Width
2.969 inches maximum
-
Body Height
3.500 inches maximum
-
Inclosure Type
open
-
Mounting Facility Quantity
4 single group
-
Winding Operating Current
90.0 milliamperes ac maximum single component 2nd secondary
-
Winding Operating Voltage
115.00 ac volts nominal single component single primary
-
Winding Operating Voltage
6.30 ac volts nominal single component 1st secondary
-
Terminal Type And Quantity
10 wire lead
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.250 inches nominal single mounting facility single center group
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.625 inches nominal single mounting facility single center group
-
Frequency Rating
60.0 hertz nominal single component
-
Maximum Operating Temp
105.0 deg celsius
-
Mounting Method
flange and slot single group
-
Winding Function And Quantity
1 primary and 3 secondary single component
-
Winding Tap Location
center tap single component 1st secondary
-
Winding Tap Location
center tap single component single primary
-
Winding Operating Current
3.0 amperes ac maximum single component 3rd secondary
-
Winding Operating Current
3.5 amperes ac maximum single component 1st secondary
-
Winding Operating Voltage
5.00 ac volts nominal single component 3rd secondary
-
Winding Operating Voltage
700.00 ac volts nominal single component 2nd secondary