38B475-2
Coils and Transformers
TRANSFORMER,POWER
38B475-2
Northrop Grumman Systems Corporation
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Winding Function And Quantity
1 primary single component and 1 secondary single component
-
Winding Operating Current
400.0 milliamperes ac maximum single component single secondary
-
Mounting Method
unthreaded hole single group
-
Reliability Indicator
not established
-
Frequency Rating
400.0 hertz nominal single component
-
Terminal Type And Quantity
15 tab, solder lug
-
Input-Output Phase Relationship
single phase to single phase single component
-
Body Width
1.500 inches nominal
-
~1
nominal single component single primary
-
~1
volts nominal single component single secondary
-
Winding Operating Voltage
120.00 ac volts nominal single component single primary and 96.00 ac volts nominal single component single primary and 48.00 ac volts nominal single component single primary and 83.00 ac volts nominal single component single primary and 128.00 ac volts
-
Winding Operating Voltage
72.00 ac volts nominal single component single secondary and 84.00 ac volts nominal single component single secondary and 36.00 ac volts nominal single component single secondary and 60.00 ac volts nominal single component single secondary and 24.00 ac
-
Mounting Facility Quantity
4 single group
-
Distance Between Mounting Facility Centers
0.875 inches nominal single mounting facility single center group and 2.438 inches nominal single mounting facility single center group
-
Body Height
3.438 inches nominal
-
Body Length
2.875 inches nominal
-
Inclosure Type
fully inclosed