005472

Coils and Transformers

TRANSFORMER,POWER

005472

5950-00-301-3695

5950 - Coils and Transformers

Ge Aviation Systems Llc

TRANSFORMER,POWER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Mounting Facility Quantity

    4 single group

  • Transformer Winding Connection Type

    wye-wye

  • Overall Width

    5.000 inches maximum

  • Winding Operating Voltage

    9.40 ac volts minimum single component 1st secondary and 9.59 ac volts maximum single component 1st secondary

  • Input-Output Phase Relationship

    three phase to six phase single component

  • Center To Center Distance Between Mounting Facilities Parallel To Width

    2.375 inches nominal single mounting facility single center group

  • Winding Operating Voltage

    180.00 ac volts minimum single component single primary and 220.00 ac volts maximum single component single primary

  • Body Height

    2.750 inches nominal

  • Winding Function And Quantity

    1 primary single component and 3 primary single component

  • Winding Operating Voltage

    18.50 ac volts minimum single component 2nd secondary and 18.87 ac volts maximum single component 2nd secondary

  • Terminal Type And Quantity

    34 tab, solder lug

  • Winding Operating Voltage

    18.50 ac volts minimum single component 3rd secondary and 18.87 ac volts maximum single component 3rd secondary

  • Frequency Rating

    380.0 hertz minimum single component and 420.0 hertz maximum single component

  • Center To Center Distance Between Mounting Facilities Parallel To Length

    3.750 inches nominal single mounting facility single center group

  • Mounting Method

    bracket single group and slot single group

  • Winding Operating Current

    15.0 amperes dc maximum single component 2nd secondary

  • Maximum Operating Temp

    170.0 deg celsius

  • Inclosure Type

    fully inclosed

  • Mounting Slot Width

    0.375 inches nominal single group

  • Winding Shielding Method

    internal shield brought out to terminal single component

  • Special Features

    all currents rated as rectified

  • Reliability Indicator

    not established

  • Winding Operating Current

    36.0 amperes dc maximum single component 1st secondary

  • Unpackaged Unit Weight (Non-Core)

    15.000 pounds

  • Body Length

    6.250 inches maximum

  • Winding Operating Current

    8.0 amperes dc maximum single component 3rd secondary

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...