WE2189
Coils and Transformers
TRANSFORMER,POWER
WE2189
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Reliability Indicator
not established
-
Maximum Operating Temp
130.0 deg celsius
-
Winding Operating Voltage
184.00 ac volts minimum single component single primary and 216.00 ac volts maximum single component single primary
-
Winding Shielding Method
internally shielded single component
-
Input-Output Phase Relationship
three phase to three phase single component and three phase to single phase single component
-
Mounting Hole Diameter
0.148 inches minimum single group and 0.165 inches maximum single group
-
Winding Operating Current
1.5 amperes dc maximum single component 2nd secondary
-
Body Height
1.630 inches maximum
-
Winding Operating Current
3.0 amperes dc maximum single component 1st secondary
-
Mounting Facility Quantity
4 single group
-
Overall Width
2.750 inches maximum
-
Winding Operating Current
2.1 amperes dc maximum single component 3rd secondary
-
Body Length
3.630 inches maximum
-
Frequency Rating
380.0 hertz minimum single component and 420.0 hertz maximum single component
-
Unpackaged Unit Weight (Non-Core)
2.250 pounds
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.438 inches nominal single mounting facility single center group
-
Winding Operating Current
0.5 amperes dc maximum single component 4th secondary
-
Mounting Method
flange single group and unthreaded hole single group
-
Winding Function And Quantity
1 primary single component and 7 secondary single component
-
Inclosure Type
fully inclosed
-
Winding Operating Voltage
21.50 ac volts minimum single component 1st secondary and 24.50 ac volts maximum single component 1st secondary
-
Winding Operating Voltage
21.50 ac volts minimum single component 2nd secondary and 24.50 ac volts maximum single component 2nd secondary
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.000 inches nominal single mounting facility single center group
-
Terminal Type And Quantity
24 tab, solder lug
-
Winding Operating Voltage
21.50 ac volts minimum single component 3rd secondary and 24.50 ac volts maximum single component 3rd secondary
-
Winding Operating Voltage
21.50 ac volts minimum single component 4th secondary and 24.50 ac volts maximum single component 4th secondary
-
Special Features
1primary,7 secondary windings; all currents are shown as rectified; secondaries 6 and 7 are rated the same,0.1 amp dc at 16.5 and 19.5 volts rms; 5th secondary is 0.57 amps at 21.50 and 24.50 volts rms
-
Transformer Winding Connection Type
delta-delta