W72-908KMG6

Circuit Breakers

CIRCUIT BREAKER

W72-908KMG6

5925-00-303-9694

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Body Style

    8c multipole-multiple actuator type

  • Body Length

    2.500 inches nominal

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.938 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Iii Fragility Factor

    moderately rugged

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Iii Special Handling Feature

    magnetic

  • Thread Quantity Per Inch

    32

  • Maximum Continuous Load Current Rating Per Pole

    3.0 amperes ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Trip Release Characteristic

    time delay all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    150.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Actuator Function

    trip-reset

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

  • Nominal Thread Size

    0.138 inches

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    6 threaded stud

  • Body Width

    2.250 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.060 inches nominal

  • Boss Height

    0.150 inches nominal

  • Mounting Surface To Terminal End Distance

    2.611 inches nominal

  • Iii Arc Quenching Method

    magnetic blowout

  • Iii Storage Type

    general purpose warehouse

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    magnetic-hydraulic all locations

  • Reset Method

    manual

  • Manual Actuator Type And Quantity

    3 toggle

  • Actuator Position Designation

    at each pole

  • Trip Delay Time In Seconds Per Rated Continuous Current

    20.000 minimum at 200 pct and 75.000 maximum at 200 pct all locations

  • Inclosure Protection Type For Which Designed

    dustproof

  • Frequency In Hertz

    400.0 all locations

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...