72-125-71MG6

Circuit Breakers

CIRCUIT BREAKER

72-125-71MG6

5925-00-306-2828

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Actuator Position Designation

    at each pole

  • Reset Method

    manual

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.046 inches minimum and 2.078 inches maximum

  • Switch Location And Position Designation

    internal at pole three

  • Storage Type

    general purpose warehouse

  • Trip Release Characteristic

    time delay all locations

  • Actuator Function

    trip-reset

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Thread Quantity Per Inch

    32

  • Arc Quenching Method

    magnetic blowout

  • Boss Height

    0.140 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    15.0 amperes ac all locations

  • ~1

    data on certain environmental and performanc

  • Terminal Type And Quantity

    6 threaded stud

  • Case Material

    plastic

  • Trip Delay Time In Seconds Per Rated Continuous Current

    2.200 minimum at 200 pct all locations and 20.000 maximum at 200 pct all locations

  • Specification/Standard Data

    81349-mil-c-55629/6 government specification

  • Manual Actuator Type And Quantity

    3 toggle

  • Body Length

    2.510 inches maximum

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 all locations

  • Main Contact Tripping Mechanism Type

    trip free

  • Frequency In Hertz

    60.0 all locations

  • Nominal Thread Size

    0.138 inches

  • Thread Pitch Diameters

    +0.1144/+0.1214 inches

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Inclosure Protection Type For Which Designed

    fungus resistant and moisture resistant

  • Mounting Surface To Terminal End Distance

    2.553 inches maximum

  • Switch Contact Arrangement

    single pole, double throw

  • Body Style

    multipole-multiple actuator type

  • Switch Current Rating And Type In Amps

    10.0 ac and 2.0 dc

  • Trip Release Method

    magnetic all locations

  • Body Width

    2.205 inches minimum and 2.285 inches maximum

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Thread Series Designator

    unc

  • Circuit Protection Type

    overcurrent all locations

  • Pole Quantity

    3

  • Special Handling Feature

    magnetic

  • Center To Center Distance Between Terminals Parallel To Length

    1.660 inches minimum and 1.960 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Switch Terminal Type

    tab, solder lug

  • Fragility Factor

    moderately rugged

  • Test Data Document

    81349-mil-c-55629 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...