APL-111-1R0-61-303-M

Circuit Breakers

CIRCUIT BREAKER

APL-111-1R0-61-303-M

5925-00-307-4008

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Case Material

    plastic

  • Center To Center Distance Between Terminals Parallel To Length

    1.660 inches minimum and 1.960 inches maximum

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.046 inches minimum and 2.078 inches maximum

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Fragility Factor

    moderately rugged

  • Boss Height

    0.140 inches nominal

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    6 threaded hole

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac all locations

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac all locations

  • Trip Release Characteristic

    time delay all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    3 toggle

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Nominal Thread Size

    0.138 inches

  • Switch Location And Position Designation

    internal at pole three

  • Switch Terminal Type

    tab, solder lug

  • Frequency In Hertz

    60.0

  • Specification/Standard Data

    81349-mil-c-55629/6 government specification

  • Thread Pitch Diameters

    +0.1177/+0.1214 inches

  • Body Style

    8c multipole-multiple actuator type

  • Body Length

    2.510 inches maximum

  • Body Width

    2.205 inches minimum and 2.285 inches maximum

  • Switch Contact Arrangement

    single pole, double throw

  • Mounting Surface To Terminal End Distance

    2.553 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Storage Type

    general purpose warehouse

  • Special Handling Feature

    magnetic

  • Thread Quantity Per Inch

    32

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    magnetic all locations

  • Reset Method

    manual

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.130 minimum at 200 pct and 1.600 maximum at 200 pct all locations

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Switch Current Rating And Type In Amps

    10.0 ac and 2.0 dc

  • Switch Voltage Rating And Type In Volts

    250.0 ac and 50.0 dc

  • Test Data Document

    81349-mil-c-55629 specification

  • Thread Series Designator

    unc

  • Terminal Type And Quantity

    6 threaded stud

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...