226245-000
Coils and Transformers
TRANSFORMER,POWER
226245-000
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Facility Quantity
4 single group
-
Winding Operating Voltage
10.30 dc volts nominal single component 3rd secondary
-
Winding Operating Voltage
19.40 dc volts nominal single component 1st secondary
-
Winding Function And Quantity
1 primary single component and 6 secondary single component
-
Winding Operating Voltage
23.60 dc volts nominal single component 2nd secondary
-
Frequency Rating
380.0 hertz minimum single component and 420.0 hertz maximum single component
-
Winding Operating Voltage
183.60 ac volts minimum single component single primary and 207.70 ac volts maximum single component single primary
-
Nominal Thread Size
0.112 inches single group
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.245 inches minimum single mounting facility single center group and 2.255 inches maximum single mounting facility single center group
-
Body Width
2.750 inches maximum
-
Winding Power Rating
32.6 volts-amperes single component 4th secondary
-
Body Height
2.250 inches maximum
-
Mounting Method
threaded hole single group
-
Inclosure Type
fully inclosed
-
Winding Power Rating
127.7 volts-amperes single component 3rd secondary
-
Input-Output Phase Relationship
three phase to three phase single component
-
Winding Shielding Method
internal shield brought out to terminal single component
-
Winding Operating Current
20.0 milliamperes dc maximum single component 1st secondary
-
Center To Center Distance Between Mounting Facilities Parallel To Length
3.620 inches minimum single mounting facility single center group and 3.630 inches maximum single mounting facility single center group
-
Winding Operating Voltage
23.30 dc volts nominal single component 4th secondary
-
Unpackaged Unit Weight (Non-Core)
3.700 pounds
-
Reliability Indicator
not established
-
Body Length
4.125 inches maximum
-
Maximum Operating Temp
130.0 deg celsius
-
Terminal Type And Quantity
25 turret
-
Winding Operating Current
12.4 amperes dc maximum single component 3rd secondary
-
Winding Power Rating
0.388 volts-amperes single component 1st secondary
-
Thread Series Designator
unc single group
-
Transformer Winding Connection Type
delta-wye
-
Thread Direction (Non-Core)
err-070
-
Winding Operating Current
1.4 amperes dc maximum single component 4th secondary
-
Special Features
one primary winding and six secondary windings