17-13406-1

Switches

SWITCH,THERMOSTATIC

17-13406-1

5930-00-311-2347

5930 - Switches

Textron Systems Corporation

SWITCH,THERMOSTATIC

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Test Data Document

    81349-mil-s-24236 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • ~1

    data on certain environmental and performanc

  • Contact Adjustability

    deactuation point not adjustable and actuation point not adjustable

  • Mounting Facility Pattern

    two position in-line

  • Body Diameter

    0.540 inches minimum and 0.640 inches maximum

  • Contact Stimulus Rating

    192.00 actuation point nominal degrees fahrenheit and 219.00 deactuation point nominal degrees fahrenheit

  • Operating Temp Rating

    -65.0 deg fahrenheit minimum and 500.0 deg fahrenheit maximum

  • Overall Height

    0.659 inches nominal

  • Style Designator

    disc w/flange

  • Overall Length

    1.160 inches minimum and 1.260 inches maximum

  • Mounting Method

    bracket and slot and unthreaded hole

  • Features Provided

    hermetically sealed case

  • Distance Between Mounting Facility Centers

    0.937 inches nominal

  • Terminal Type

    tab, solder lug

  • Unthreaded Mounting Hole Diameter

    0.140 inches nominal

  • Temp Sensing Element Type

    internal sensor

  • Body Height

    0.280 inches minimum and 0.395 inches maximum

  • Mounting Slot Width

    0.140 inches nominal

  • Media For Which Designed

    gas or liquid

  • Contact Voltage Rating In Volts

    115.0 ac at sea level first voltage

  • Frequency In Hertz

    60.0 first voltage

  • Specification/Standard Data

    81349-mil-s-24236/1 government specification

  • Nonpile-Up Contact Arrangement

    1 pole, single throw, normally closed, momentary action

  • Contact Load Current Rating

    2.0 amperes resistive load first voltage and 1.0 amperes inductive load first voltage and 500.0 milliamperes lamp load first voltage

  • Contact Load Current Rating

    5.0 amperes resistive load second voltage and 2.5 amperes inductive load second voltage and 1.0 amperes lamp load second voltage

  • Contact Action Stimulus

    decrease

  • Contact Voltage Rating In Volts

    28.0 dc at sea level second voltage

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...