Technical Characteristics

  • ~1

    data on certain environmental and performanc

  • Test Data Document

    81349-mil-c-55629 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.062 inches nominal

  • Terminal Type And Quantity

    2 threaded stud

  • Specification/Standard Data

    81349-mil-c-55629/2 government specification

  • Center To Center Distance Between Terminals Parallel To Length

    1.938 inches nominal

  • Case Material

    plastic

  • Maximum Continuous Load Current Rating Per Pole

    30.0 amperes ac single location

  • Switch Location And Position Designation

    internal at pole one

  • Switch Voltage Rating And Type In Volts

    240.0 ac and 50.0 dc

  • Body Width

    1.500 inches nominal

  • Auxiliary Switch Function And Quantity

    1 alarm

  • Thread Pitch Diameters

    +0.1177/+0.1214 inches

  • Frequency In Hertz

    60.0 single location

  • Body Style

    single pole type

  • Boss Height

    0.140 inches nominal

  • Body Length

    2.500 inches nominal

  • Arc Quenching Method

    magnetic blowout

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width

    0.750 inches nominal

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Trip Release Characteristic

    time delay single location

  • Mounting Surface To Terminal End Distance

    2.471 inches nominal

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Pole Quantity

    1

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Reset Method

    manual

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    3.000 minimum at 200 pct single location and 9.450 maximum at 200 pct single location

  • Thread Series Designator

    unc

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac single location

  • Special Handling Feature

    magnetic

  • Center To Center Distance Between Terminals Parallel To Width

    0.750 inches nominal

  • Switch Terminal Type

    tab, solder lug

  • Trip Release Method

    magnetic single location

  • Fragility Factor

    moderately rugged

  • Switch Current Rating And Type In Amps

    1.0 ac and 1.0 dc

  • Switch Contact Arrangement

    single pole, double throw

  • Inclosure Protection Type For Which Designed

    fungus resistant

  • Circuit Protection Type

    overcurrent single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...