FBD124
Filters and Networks
FILTER,BAND PASS
FBD124
FILTER,BAND PASS
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Inclosure Type
encased
-
Unthreaded Mounting Hole Diameter
0.136 inches nominal
-
Discrimination At Specified Frequencies Per Function In Decibels
70.0 minimum 2nd band pass and 2.0 maximum 2nd band pass and 2.0 maximum 2nd band pass and 70.0 minimum 2nd band pass
-
Output Terminal Identification
12819female
-
Specified Frequencies Of Discrimination Per Function
43.00 megahertz 1st band pass and 25.00 megahertz 1st band pass and 77.00 megahertz 1st band pass and 95.00 megahertz 1st band pass
-
Voltage Standing Wave Ratio Frequency Limits Per Function
43.0 hercules no.5599.1 two phase to two phase and 77.0 hercules no.5599.1 two phase to two phase
-
Reference Frequency Per Function
60.0 hercules no.5599.1 pulses per second
-
Output Terminal Manufacturer Code
92755
-
Reference Frequency Per Function
60.0 hercules no.5599.1 two phase to two phase
-
Voltage Standing Wave Ratio Per Function
1.5 1st band pass
-
Overall Length
4.250 inches nominal
-
Functional Terminal Type And Quantity
1 connector, receptacle input 1st function
-
Voltage Standing Wave Ratio Per Function
1.5 2nd band pass
-
Input Terminal Manufacturer Code
92755
-
Style Designator
rectangular terminal/terminals on opposite surfaces
-
Insertion Loss At Reference Frequency Per Function In Decibels
2.0 1st band pass
-
Specified Frequencies Of Discrimination Per Function
43.00 megahertz 2nd band pass and 25.00 megahertz 2nd band pass and 77.00 megahertz 2nd band pass and 95.00 megahertz 2nd band pass
-
Mounting Facility Type And Quantity
2 unthreaded hole
-
Insertion Loss At Reference Frequency Per Function In Decibels
2.0 2nd band pass
-
Frequency Band Width Per Function
43.00 megahertz 1st band pass and 77.00 megahertz 1st band pass
-
Mounting Facility Screw Thread Series Designator
unc
-
Nominal Thread Size
0.112 inches
-
Input Terminal Identification
12819female
-
Overall Height
0.650 inches maximum
-
Voltage Standing Wave Ratio Frequency Limits Per Function
43.0 hercules no.5599.1 pulses per second and 77.0 hercules no.5599.1 pulses per second
-
Frequency Band Width Per Function
43.00 megahertz 2nd band pass and 77.00 megahertz 2nd band pass
-
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
3.750 inches maximum
-
Functional Terminal Type And Quantity
1 connector, receptacle output 2nd function
-
Body Width
1.500 inches nominal
-
Discrimination At Specified Frequencies Per Function In Decibels
2.0 maximum 1st band pass and 70.0 minimum 1st band pass and 2.0 maximum 1st band pass and 70.0 minimum 1st band pass