X0415-60-120-240-60-1

Circuit Breakers

CIRCUIT BREAKER

X0415-60-120-240-60-1

5925-00-327-9371

5925 - Circuit Breakers

Eaton Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Maximum Continuous Load Current Rating Per Pole

    60.0 amperes ac single location

  • Case Material

    plastic

  • Frequency In Hertz

    60.0 single location

  • Trip Release Method

    magnetic-hydraulic single location

  • Body Style

    single pole type

  • Trip Delay Time In Seconds Per Rated Continuous Current

    40.000 minimum at 200 pct single location and 100.500 maximum at 200 pct single location

  • Inclosure Protection Type For Which Designed

    general purpose

  • Terminal Type And Quantity

    1 tab w/screw and 1 compression

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.740 inches minimum and 2.760 inches maximum

  • Arc Quenching Method

    magnetic blowout

  • Main Contact Tripping Mechanism Type

    trip free

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Trip Release Characteristic

    time delay single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    5000.0 ac single location

  • Nominal Thread Size

    0.138 inches

  • Internal Trip Release Configuration

    series trip single location

  • Manual Actuator Type And Quantity

    1 toggle

  • Pole Quantity

    1

  • Unpackaged Unit Weight

    0.688 pounds

  • Center To Center Distance Between Terminals Parallel To Length

    4.303 inches minimum and 4.323 inches maximum

  • Body Length

    4.740 inches minimum and 4.760 inches maximum

  • Circuit Protection Type

    overcurrent single location

  • Thread Quantity Per Inch

    32

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Body Width

    1.020 inches minimum and 1.040 inches maximum

  • Body Height

    2.820 inches minimum and 2.840 inches maximum

  • Actuator Function

    trip-reset

  • Storage Type

    general purpose warehouse

  • Actuator Position Designation

    at pole one

  • Reset Method

    manual

  • Thread Series Designator

    unc

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac single location

  • Special Handling Feature

    magnetic

  • Fragility Factor

    moderately rugged

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...