MS3320-5L

Circuit Breakers

CIRCUIT BREAKER

MS3320-5L

5925-00-328-3885

5925 - Circuit Breakers

Military Standards

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Bushing Length

    0.250 inches nominal

  • Reset Method

    manual

  • Trip Release Ambient Temp Rating

    25.0 deg celsius maximum single location

  • Actuator Position Designation

    at pole one

  • Body Length

    0.781 inches maximum

  • Storage Type

    general purpose warehouse

  • Actuator Function

    trip-reset

  • Terminal Type And Quantity

    2 screw

  • Mounting Surface To Terminal End Distance

    1.343 inches maximum

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2500.0 ac single location

  • Specification/Standard Data

    96906-ms3320 government standard

  • Test Data Document

    81349-mil-c-5809 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • ~1

    data on certain environmental and performance

  • Maximum Continuous Load Current Rating Per Pole

    5.0 amperes ac single location

  • Thread Quantity Per Inch

    32

  • Nominal Thread Size

    0.438 inches

  • Circuit Protection Type

    overcurrent single location

  • Trip Release Method

    thermal single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Operating Voltage Type And Rating Per Pole In Volts

    115.0 ac single location

  • Manual Actuator Type And Quantity

    1 push-pull

  • Center To Center Distance Between Terminals Parallel To Length

    0.500 inches nominal

  • Pole Quantity

    1

  • Internal Trip Release Configuration

    series trip single location

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • Trip Delay Time In Seconds Per Rated Continuous Current

    3.000 minimum at 200 pct single location and 30.000 maximum at 200 pct single location

  • Frequency In Hertz

    400.0 single location

  • Body Style

    single pole type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    138.0 single location

  • Body Width

    0.593 inches maximum

  • Thread Series Designator

    uns

  • Case Material

    plastic

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...