10526146

Circuit Breakers

CIRCUIT BREAKER

10526146

5925-00-329-2071

5925 - Circuit Breakers

U S Army Armament Research &

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Trip Delay Time In Seconds Per Rated Continuous Current

    10.000 minimum at 125 pct and 40.000 maximum at 125 pct all locations

  • Inclosure Protection Type For Which Designed

    dustproof and hermetically sealed

  • Body Style

    3c multipole-multiple actuator type

  • Body Length

    1.688 inches nominal

  • Case Material

    metal

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Center To Center Distance Between Terminals Parallel To Width

    0.688 inches nominal

  • Mounting Surface To Terminal End Distance

    1.605 inches nominal

  • Maximum Continuous Load Current Rating Per Pole

    3.0 amperes ac all locations

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac all locations

  • Circuit Protection Type

    overcurrent all locations

  • Trip Release Method

    magnetic all locations

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 all locations

  • External Actuator Linkage Arrangement

    one, two, and three linked

  • Internal Trip Release Configuration

    series trip all locations

  • Nominal Thread Size

    0.375 inches

  • Frequency In Hertz

    400.0 all locations

  • Thread Series Designator

    unef

  • Terminal Type And Quantity

    6 wire hook

  • Bushing Length

    0.375 inches nominal

  • Body Width

    1.812 inches nominal

  • Pole Quantity

    3

  • Mounting Facility Type And Quantity

    3 threaded bushing

  • Thread Quantity Per Inch

    32

  • Operating Voltage Type And Rating Per Pole In Volts

    120.0 ac all locations

  • Trip Release Characteristic

    time delay all locations

  • Reset Method

    manual

  • Main Contact Tripping Mechanism Type

    trip free

  • Manual Actuator Type And Quantity

    3 toggle

  • Actuator Function

    trip-reset

  • Actuator Position Designation

    at each pole

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...