C16111
Coils and Transformers
TRANSFORMER,POWER
C16111
A Merrie Sweepe Chimney Service
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Winding Operating Voltage
10.50 dc volts nominal single component 1st secondary and 26.20 dc volts nominal single component 1st secondary and 33.00 dc volts nominal single component 1st secondary
-
Winding Operating Voltage
115.00 ac volts minimum single component single primary and 201.00 ac volts maximum single component single primary
-
Thread Series Designator
unc 1st group
-
Winding Operating Voltage
26.00 ac volts nominal single component 4th secondary
-
Winding Tap Location (Non-Core)
err-070
-
Maximum Operating Temp
155.0 deg celsius
-
Winding Function And Quantity
1 primary single component and 7 secondary single component
-
Winding Operating Voltage
74.50 ac volts nominal single component 2nd secondary
-
Inclosure Type
fully inclosed
-
Overall Length
3.530 inches maximum
-
Features Provided
w/rectifier and color coded lead
-
Winding Operating Current
5.0 amperes dc maximum single component 1st secondary
-
Mounting Hole Diameter
0.148 inches minimum 2nd group and 0.165 inches maximum 2nd group
-
Mounting Method
unthreaded hole 2nd group
-
Transformer Winding Connection Type
wye-open delta and wye-wye
-
Winding Operating Current
130.0 milliamperes ac maximum single component 3rd secondary
-
Winding Operating Voltage
36.00 ac volts nominal single component 3rd secondary
-
Mounting Facility Quantity
4 all groupings
-
Overall Width
2.580 inches minimum and 2.680 inches maximum
-
Terminal Type And Quantity
31 wire lead
-
Input-Output Phase Relationship
three phase to three phase single component and three phase to single phase single component
-
Mounting Method
threaded hole 1st group
-
Special Features
voltages and currents have been rectified for the first secondary
-
Unpackaged Unit Weight (Non-Core)
1.700 pounds
-
Winding Operating Current
230.0 milliamperes ac maximum single component 4th secondary
-
Center To Center Distance Between Mounting Facilities Parallel To Length
2.428 inches minimum all mounting facilities single center group and 2.448 inches maximum all mounting facilities single center group
-
Body Height
1.420 inches maximum
-
Thread Class (Non-Core)
err-070
-
Frequency Rating
400.0 hertz nominal single component
-
Reliability Indicator
not established
-
Center To Center Distance Between Mounting Facilities Parallel To Width
1.990 inches minimum all mounting facilities single center group and 2.010 inches maximum all mounting facilities single center group
-
Nominal Thread Size
0.138 inches 1st group
-
Test Data Document
07187-4010238 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)