AP1-1-6-1-203

Circuit Breakers

CIRCUIT BREAKER

AP1-1-6-1-203

5925-00-350-1375

5925 - Circuit Breakers

Sensata Technologies Maryland Inc

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Terminal Type And Quantity

    2 wire hook

  • Operating Voltage Type And Rating Per Pole In Volts

    240.0 ac single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    1000.0 ac single location

  • Reset Method

    manual

  • Actuator Position Designation

    at pole one

  • Actuator Function

    trip-reset

  • Thread Pitch Diameters

    +0.3503/+0.3537 inches

  • Nominal Thread Size

    0.375 inches

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • Mounting Facility Type And Quantity

    1 threaded bushing

  • Inclosure Protection Type For Which Designed

    hermetically sealed

  • Center To Center Distance Between Terminals Parallel To Length

    0.875 inches nominal

  • Pole Quantity

    1

  • Manual Actuator Type And Quantity

    1 toggle

  • Internal Trip Release Configuration

    series trip single location

  • Body Length

    1.500 inches maximum

  • Trip Release Characteristic

    time delay single location

  • Main Contact Tripping Mechanism Type

    trip free

  • ~1

    single location

  • Trip Delay Time In Seconds Per Rated Continuous Current

    0.020 minimum at 300 pct single location and 0.600 maximum at 200 pct single location and 0.200 maximum at 300 pct single location and 0.010 minimum at 400 pct single location and 0.090 minimum at 200 pct single location and 0.070 maximum at 400 pct

  • Case Material

    plastic

  • Bushing Length

    0.380 inches maximum

  • Thread Series Designator

    unef

  • Frequency In Hertz

    60.0 single location

  • Mounting Surface To Terminal End Distance

    1.605 inches maximum

  • Trip Release Method

    magnetic-hydraulic single location

  • Body Width

    0.625 inches maximum

  • Body Style

    single pole type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    115.0 single location

  • Maximum Continuous Load Current Rating Per Pole

    20.0 amperes ac single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.
Read more...