2184253

Circuit Breakers

CIRCUIT BREAKER

2184253

5925-00-350-4589

5925 - Circuit Breakers

General Motors Corp

CIRCUIT BREAKER

ACT NOW! SUBMIT A QUICK QUOTE.

Technical Characteristics

  • Inclosure Protection Type For Which Designed

    moisture resistant

  • Body Width

    1.875 inches nominal

  • Nominal Thread Size

    0.190 inches

  • Thread Series Designator

    unf

  • Operating Voltage Type And Rating Per Pole In Volts

    28.0 dc single location

  • Maximum Continuous Load Current Rating Per Pole

    105.0 amperes dc single location

  • Terminal Type And Quantity

    2 screw

  • Mounting Facility Type And Quantity

    2 threaded hole

  • Thread Quantity Per Inch

    32

  • Circuit Protection Type

    overcurrent single location

  • ~1

    data on certain environmental and performanc

  • Case Material

    plastic

  • Overall Length

    3.156 inches nominal

  • Center To Center Distance Between Terminals Parallel To Length

    1.062 inches nominal

  • Reset Method

    automatic

  • Trip Delay Time In Seconds Per Rated Continuous Current

    30.000 nominal at 200 pct single location

  • Mounting Surface To Terminal End Distance

    1.406 inches nominal

  • Body Style

    single pole type

  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent

    125.0 single location

  • Trip Release Ambient Temp Rating

    25.0 deg celsius nominal single location

  • Test Data Document

    81348-mil-c-13516 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type

  • Trip Release Characteristic

    time delay single location

  • Internal Trip Release Configuration

    series trip single location

  • Pole Quantity

    1

  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length

    2.406 inches nominal

  • Arc Quenching Method

    air

  • Trip Release Method

    thermal single location

  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps

    2000.0 dc single location

Certified to
AS6081 Methods

Implementing Quality Procurement

A rigorous vendor selection process and vendor management system are essential to ensuring quality.
Read more...

Supplying Quality Products

We take every measure to ensure that we supply quality, authentic parts including a strict vendor selection process and rigorous product inspections..
Read more...

Providing Quality People

Our team of dedicated account managers, procurement professionals and specialized inspectors is the most valuable resource we have.