402816
Coils and Transformers
TRANSFORMER,POWER
402816
TRANSFORMER,POWER
ACT NOW! SUBMIT A QUICK QUOTE.
Technical Characteristics
-
Mounting Facility Quantity
4 single group
-
Center To Center Distance Between Mounting Facilities Parallel To Width
2.620 inches nominal single mounting facility single center group
-
Input-Output Phase Relationship
single phase to single phase single component
-
Winding Operating Current
2.4 amperes dc maximum single component single secondary
-
Winding Operating Voltage
44.00 ac volts nominal single component single secondary
-
Center To Center Distance Between Mounting Facilities Parallel To Length
3.000 inches nominal single mounting facility single center group
-
Reliability Indicator
not established
-
Frequency Rating
45.0 hertz minimum single component and 440.0 hertz maximum single component
-
Terminal Type And Quantity
7 tab, solder lug
-
Winding Function And Quantity
1 primary single component and 1 secondary single component
-
Inclosure Type
fully inclosed
-
Body Width
3.500 inches maximum
-
Mounting Method
slot single group
-
Mounting Slot Width
0.203 inches nominal single group
-
Winding Operating Voltage
98.00 ac volts minimum single component single primary and 132.00 ac volts maximum single component single primary
-
Maximum Operating Temp
90.0 deg celsius
-
Body Height
4.940 inches maximum
-
Body Length
4.000 inches maximum